Core Count: 3P, 4P, 5P
Category: Male
Installation Method: Welding wire type
Applications: Power, Signal
Panel-mounted soldered wire with shielding:
Shielding structure design: Adopting the Faraday cage design of "metal enclosure + 360° seamless connection of shielding layer", the shielding layer (tinned copper woven mesh or metal foil) is directly connected to the metal enclosure of the connector, forming a closed electromagnetic isolation space. The shielding efficiency can effectively attenuate the electromagnetic radiation interference generated by industrial motors, frequency converters, and transformers. Shielding connection process: Through the connection structure of crimping flanges or threaded rings, ensure that the cable shielding layer is fully in contact with the connector enclosure, eliminate the signal leakage path, guarantee the continuity of shielding, and avoid interference penetration caused by shielding breakage. Focusing on the complex industrial electromagnetic environment and the requirements of bus transmission, the core application is: industrial bus systems, automated production lines, mobile industrial equipment.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12BM-03R2LSLSS301 |
3
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BM-04R2LSLSS301 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BM-05R2LSLSS301 |
5
|
4A
|
60V
|
60V
|
22
|
0.34
|
| Core | 2A | 3A | 4A | 5A |
| male |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".