Core Count: 8P
Category: Female
Direction: 90°
Application: Power, Signal
Assembly-type bent 90-degree male connector with metal shielding tape:
High adaptability on-site: The assembly feature breaks the installation limitations of integrated connectors. On-site, the wiring and assembly can be completed flexibly according to the cable specifications. In the future, if the cable is damaged or the terminal fails, there is no need to replace the entire connector. Only the corresponding components need to be repaired, reducing maintenance costs and downtime. Space and wiring-friendly: The 90-degree bent design allows the cable to run along the edge of the equipment housing or PCB board. Compared to straight connectors, it significantly reduces space occupation. It is particularly suitable for devices with limited internal space such as industrial robot joints, small sensors, and compact switches, avoiding connection loosening caused by pulling the cable. Dual protection against protection and interference: The full metal housing not only has higher hardness than plastic housing, but can also withstand minor collisions and chemical medium erosion in industrial environments. Its 360° shielding structure can precisely block EMI electromagnetic interference, ensuring stable transmission of high-speed data in complex industrial environments and avoiding equipment mis-triggering caused by signal crosstalk.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12XF-08N4LSLPR601 |
8
|
2A
|
30V
|
30V
|
24
|
0.25
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".