Core Count: 8P
Category: Female
Connection Method: Plug-in type
Application: Power, Signal
Panel-type PCB front lock:
Installation and maintenance efficiency: The front lock design allows for direct pre-fixation from the front panel through threads, with 3 - 5 turns being sufficient to temporarily fix the position. There is no need to hold and fix the connector, making it convenient for calibrating the PCB board's welding position. Compared to the rear lock model, the installation efficiency is significantly improved. During subsequent maintenance, there is no need to disassemble the equipment casing, which greatly reduces maintenance costs and is suitable for already assembled equipment. High connection accuracy and stability: The PCB-type terminals are directly soldered onto the circuit board, reducing additional wiring steps. This not only reduces human wiring errors but also strengthens the connection firmness with the circuit. In the equipment operation vibration environment, it can avoid contact problems and ensure the continuous and stable transmission of signals and data. Flexible adaptability: In addition to X encoding, it also supports A, B, D, etc. multiple encoding specifications. Different encodings can avoid interface misinsertion that causes equipment damage. The selection of core number and opening specifications is diverse, which can match the installation and transmission requirements of different integrated circuits such as industrial sensors and control boards.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12XF-08R2LSLNS301 |
8
|
2A
|
30V
|
30V
|
24
|
0.25
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".