Core Count: 4P
Category: Male
Direction:90°
Applications: Power, Signal
90-degree right-angle rubberized molding type:
90-degree curved angle space adaptation: Select the left or right curved angle model based on the installation area gap, ensuring that the inner side of the curved angle has a ≥3mm operation space reserved with the equipment shell, and there is no interference from pipelines or components on the outer side; Measure the actual cable extension path to avoid forced twisting adaptation for wiring at the curved angle, and prevent the rubberized structure from cracking due to force. Key points for curved angle and cable installation: The 90-degree curved angle must be completely consistent with the preset wiring direction. The cable should extend naturally along the curved angle, with a bending radius of ≥6 times the cable diameter. Do not over-bend or pull the cable; The IP67 protection performance and plug-and-play feature are widely applied in the signal transmission scenarios of narrow joints in industrial robots, densely wired areas in automated production lines, outdoor environmental monitoring instruments, and sensor devices of new energy equipment.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MB12DM-045LSRAXXXXX01 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".