Core Count: 3P, 4P, 5P
Category: Mother end
Installation Method: Welding wire type
Applications: Power, Signal
Square flange design: The square flange is equipped with four installation holes. The connector can be firmly fixed to the equipment panel through bolts. This design can evenly distribute external forces, enhance vibration and impact resistance, and ensure the stability of the connection.
Sealing principle: The sealing ring is usually installed at the contact area between the flange and the equipment panel, as well as at the connection part of the connector's plug and socket. When the connector is installed or connected, the sealing ring is compressed to fill the gap, thereby achieving an IP67 or higher protection level, effectively preventing dust, moisture, etc. from entering.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12BM-03L7LSLNS101 |
3
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BM-04L7LSLNS101 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BM-05L7LSLNS101 |
5
|
4A
|
60V
|
60V
|
22
|
0.34
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".