Core Count: 3P, 4P, 5P
Category: Female
Installation Method: Panel-type
Direction: 90°
Applications: Power, Signal
90-degree elbow plate-mounted connector without shielding:
Suitable for special wiring scenarios: The 90-degree elbow design can significantly save radial installation space. The cables can be laid along the edge of the equipment plate for wiring, avoiding the problem of excessive bending and damage to the straight connector cables. It is particularly suitable for industrial automation equipment with dense equipment and limited wiring space. The B-coded reverse single-key slot design can avoid incorrect insertion with other coded connectors and can also install two interfaces with different connection requirements on the same panel, suitable for fieldbus connection scenarios such as Profibus and Interbus. Reliable protection and fixation: Most products have a protection level of IP67, which can achieve dust-proof and short-term water immersion protection, suitable for outdoor or industrial workshop environments with much dust and humidity. Generally, a threaded locking structure is adopted, combined with screw wiring method, which can also maintain a firm connection in the equipment vibration environment and reduce the risk of poor contact.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12BF-03R2LDLNR101 |
3
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BF-04R2LDLNR101 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12BF-05R2LDLNR101 |
5
|
4A
|
60V
|
60V
|
22
|
0.34
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
![]() |
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".